Grouting / STAGES
Non-shrink cementitious baseplate / bolt grouting
Cementitious precision grouting for baseplates, bolts, equipment and structural bearing zones
Non Shrink Grout & Repair Materials
Non – shrink , Fluid High strength, meets Non- shrink requirements of CRD-C588-76
MC-Metal Grout is specially prepared , ready –to- use , non shrink grout. it is formulated for use at any consistency from fluid to damp – pack for grouting machines or plates requiring non- shrink , high –strength precision bearing , including machine bases subject to thermal movement. Complies with requirements of corps of engineers specification for non- shrink grout , CRD – C 588-76 .
| Mixing water per 25 kg bag | 4 L ± 10% |
|---|---|
| Approximate yield | 12 L per 25 kg |
| Approximate material requirement | 84 bags per m³ |
| Compressive strength - 1 day | 250 kg/cm² |
| Compressive strength - 3 days | 400 kg/cm² |
|---|---|
| Compressive strength - 7 days | 500 kg/cm² |
| Compressive strength - 28 days | 650 kg/cm² |
| Packaging | 25 kg moisture-resistant bag |
MC-Metal Grout is a specially prepared, ready-to-use, non-shrink grout for use from fluid to damp-pack consistency. It is intended for high-strength precision bearing beneath machines or plates, including machine bases subjected to thermal movement.
Machinery and equipment requiring high strength, maximum bearing, impact resistance and non-shrink precision grouting. Crane rail plates and rolling, stamping, drawing or finishing mills in steel and aluminium industries. Paper-machine installations. Turbines, generators and centrifugal compressors. Applications where shrinkage must be eliminated to achieve maximum load and bearing transfer. Anchor bolts and rods.
Hardens without bleeding, settlement or drying shrinkage when mixed, placed and cured at the appropriate consistency. Dense grout without gas-generating or air-release agents such as aluminium powder. Withstands thermal movement and cyclic heating/cooling and wetting/drying effects, according to the source. Ductile metallic aggregate provides higher strength and improved impact resistance under dynamic and repetitive loading. Develops strength without vertical confinement. Meets the source-referenced non-shrink requirements of CRD-C588-76.
Compressive strength - 3 days 400 kg/cm² Compressive strength - 7 days 500 kg/cm² Compressive strength - 28 days 650 kg/cm² Packaging 25 kg moisture-resistant bag
The source specifies an approximate 7-40°C temperature range for the bedplate, foundation and grout. Do not use water in an amount or at a temperature that produces a flow of less than 20 seconds under the referenced CRD-C 79-77 test or causes bleeding / segregation.
CRD-C588-76 CRD-C 79-77 flow reference, as stated by the source.