MCT ENGINEERED SYSTEM

Fiber-reinforced cementitious concrete repair

Localized concrete repair using fiber-reinforced shrinkage-compensated repair mortar

Fiber-reinforced cementitious concrete repair

CONDITIONS

Start with the site

Localized concrete repair using fiber-reinforced shrinkage-compensated repair mortar · Concrete · Repair | vertical/horizontal depending product source

A bonding primer is not included in this repair sequence.

MCT / STAGES

System stages

See each stage in context, understand its technical role and open the relevant MCT product data directly.

APPLICATION SEQUENCE

Select a stage. Follow its role to the product and technical data.

Substrate preparation

  1. Clean and remove contamination; pre-wet substrate

    System material reference; prepare the substrate as described above.

    Patch FTDS ↗
  2. Mix using MCT water range

  3. Apply by spray/shotcrete or trowel; force mortar into substrate

  4. Cure with water or curing compound as soon as possible

MCT / PRODUCT ROLES

MCT products in this system

Non Shrink Grout & Repair Materials

MC-Patch F

Shrinkage Compensated and Fiber reinforced Patching and Repair Mortar

MCT / TDS

Technical data

TDS / CURRENT

MC-Patch F

Revision 2.0 ·

PROJECT / NEXT STEP